{"id":14005,"date":"2025-07-17T15:06:36","date_gmt":"2025-07-17T13:06:36","guid":{"rendered":"https:\/\/onload.reinhausen.com\/de\/?p=14005"},"modified":"2026-04-15T11:03:36","modified_gmt":"2026-04-15T09:03:36","slug":"gis-synthetische-luft-klimafreundliche-gase-f-gasverordnung","status":"publish","type":"post","link":"https:\/\/onload.reinhausen.com\/de\/07-2025\/gis-synthetische-luft-klimafreundliche-gase-f-gasverordnung\/","title":{"rendered":"Besser f\u00fcrs Klima: Synthe\u00adti\u00adsche Luft"},"content":{"rendered":"\n<hr class=\"wp-block-separator has-alpha-channel-opacity\">\n\n\n\n<h4 class=\"wp-block-heading\">M\u00f6chten Sie wissen, wie HIGHVOLT die Heraus\u00adfor\u00adde\u00adrung gemeis\u00adtert hat? Dann einfach den Schalter nach rechts schieben!<\/h4>\n\n\n\n<div class=\"wp-block-group alignwide mgznkr-switch\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns are-vertically-aligned-top mgznkr-switch-labels is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading has-text-align-right has-normal-font-size\" style=\"font-size:36px\">Aufgabe<\/h2>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading has-text-align-left has-normal-font-size\" style=\"font-size:36px\">Ergebnis<\/h2>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns mgznkr-switch-content is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"background:linear-gradient(135deg,rgb(222,221,222) 0%,rgb(253,253,253) 100%)\">\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Die Heraus\u00adfor\u00adde\u00adrung<\/h2>\n\n\n\n<p class=\"has-text-align-left\">Schwe\u00adfel\u00adhexa\u00adfluorid (SF<sub>6<\/sub>) ist ein ideales Isoliergas f\u00fcr elek\u00adtri\u00adsche Anwen\u00addungen wie beispiels\u00adweise f\u00fcr gasiso\u00adlierte Schalt\u00adan\u00adlagen (GIS), die in Umspann\u00adwerken oder indus\u00adtri\u00adellen Anlagen den Ener\u00adgie\u00adfluss steuern, bei Bedarf Strom\u00adkreise abschalten und das Hoch\u00adspan\u00adnungs\u00adnetz vor \u00dcber\u00adlas\u00adtungen sch\u00fctzen. Dank der heraus\u00adra\u00adgenden Eigen\u00adschaften von SF<sub>6<\/sub> sind sehr kompakte Bauweisen m\u00f6glich. Im Vergleich zu Frei\u00adluft\u00adschalt\u00adan\u00adlagen nehmen GIS deut\u00adlich weniger Platz ein und eignen sich daher beson\u00adders f\u00fcr den Einsatz in urbanen Gebieten. Doch das beliebte Isoliergas hat einen gravie\u00adrenden Nach\u00adteil: eine kata\u00adstro\u00adphale Klima\u00adbi\u00adlanz. Es ist rund 23.500-mal klima\u00adsch\u00e4d\u00adli\u00adcher als CO<sub>2<\/sub> und h\u00e4lt sich zu-dem 3.200 Jahre in der Atmo\u00adsph\u00e4re. <\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns are-vertically-aligned-center is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:30%\">\n<h2 class=\"wp-block-heading has-text-align-center no-margin-bottom\" style=\"font-size:65px\"><span class=\"mgznkr-counter m4w-counter  \" data-mode=\"de\" data-delay=\"120\" data-time=\"1500\" data-val=\"3.200\">0<\/span><\/h2>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center no-margin-top no-margin-bottom\">Jahre<\/h2>\n\n\n\n<p class=\"has-text-align-center sans\" style=\"font-size:18px\">bleibt SF<sub>6<\/sub> in der Atmo\u00adsph\u00e4re.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:40%\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"651\" height=\"668\" src=\"https:\/\/onload.reinhausen.com\/de\/wp-content\/uploads\/sites\/25\/2025\/07\/Highvolt_Schwefelhexafluorid.webp\" alt class=\"wp-image-14030\" style=\"width:140px\" srcset=\"https:\/\/onload.reinhausen.com\/de\/wp-content\/uploads\/sites\/25\/2025\/07\/Highvolt_Schwefelhexafluorid.webp 651w, https:\/\/onload.reinhausen.com\/de\/wp-content\/uploads\/sites\/25\/2025\/07\/Highvolt_Schwefelhexafluorid-292x300.webp 292w, https:\/\/onload.reinhausen.com\/de\/wp-content\/uploads\/sites\/25\/2025\/07\/Highvolt_Schwefelhexafluorid-540x554.webp 540w\" sizes=\"auto, (max-width: 651px) 100vw, 651px\"><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading has-text-align-center no-margin-bottom no-margin-top\">Schwe\u00adfel\u00adhexa\u00adfluorid (SF<sub>6<\/sub>)<\/h2>\n\n\n\n<p class=\"has-text-align-center sans\" style=\"font-size:18px\">ist dank seiner hervor\u00adra\u00adgenden isolie\u00adrenden Eigen\u00adschaften das perfekte Isoliergas f\u00fcr elek\u00adtri\u00adsche Anwen\u00addungen.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:30%\">\n<h2 class=\"wp-block-heading has-text-align-center no-margin-bottom\" style=\"font-size:65px\"><span class=\"mgznkr-counter m4w-counter  \" data-mode=\"de\" data-delay=\"120\" data-time=\"1500\" data-val=\"23.500\">0<\/span><\/h2>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center no-margin-top no-margin-bottom\">mal<\/h2>\n\n\n\n<p class=\"has-text-align-center sans\" style=\"font-size:18px\">klima\u00adsch\u00e4d\u00adli\u00adcher als CO<sub>2<\/sub><\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-text-align-left\">Letztes Jahr trat in der EU daher eine neue F\u2011Gasverordnung in Kraft, die den Einsatz von fluo\u00adrierten Gasen immer mehr einschr\u00e4nkt und das SF<sub>6<\/sub>-Gas ab 2032 in neuen elek\u00adtri\u00adschen Anlagen ganz verbietet. Davon betroffen sind auch die gasiso\u00adlierten Pr\u00fcf- und Mess\u00adsys\u00adteme von HIGHVOLT, die Hersteller und auch Betreiber f\u00fcr die Pr\u00fcfung der GIS ben\u00f6\u00adtigen. Dr. Tobias Gabler von HIGHVOLT erkl\u00e4rt: \u201eDie Heraus\u00adfor\u00adde\u00adrung ist, dass es kein anderes Gas gibt, das \u00fcber \u00e4hnliche gute Eigen\u00adschaften verf\u00fcgt wie SF<sub>6<\/sub>.\u201c Zwar sind schon Alter\u00adna\u00adtiven am Markt, die eine deut\u00adlich bessere Klima\u00adbi\u00adlanz haben, aber auch sie enthalten zum Teil fluo\u00adrierte Gase, die die EU eben\u00adfalls verbieten will. \u201eF\u00fcr unsere Anlagen wollten wir eine zukunfts\u00adsi\u00adchere L\u00f6sung. Wir wollen, dass sich unsere Kunden darauf verlassen k\u00f6nnen, dass sie ihre Pr\u00fcf\u00adsys\u00adteme auch noch in zehn Jahren nutzen k\u00f6nnen\u201c, erkl\u00e4rt Gabler.<\/p>\n\n\n\n<div style=\"height:60px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"background:linear-gradient(135deg,rgb(255,253,228) 0%,rgb(254,237,1) 100%)\">\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Die L\u00f6sung<\/h2>\n\n\n\n<p class=\"has-text-align-left\">Was ist also die Alter\u00adna\u00adtive? Die Antwort h\u00f6rt sich denkbar einfach an: synthe\u00adti\u00adsche Luft. Sie besteht aus Stick\u00adstoff und Sauer\u00adstoff, hat ein Treib\u00adhaus\u00adpo\u00adten\u00adzial von null und ist damit f\u00fcr das Klima v\u00f6llig unbe\u00addenk\u00adlich. Der Haken: Synthe\u00adti\u00adsche Luft hat ein deut\u00adlich schlech\u00adteres Isolier\u00adver\u00adm\u00f6gen und kann das SF<sub>6<\/sub>-Gas nicht eins zu eins ersetzen. \u201eDie Nach\u00adteile lassen sich jedoch \u00fcber\u00adwinden, wenn wir das Design unserer Pr\u00fcf- und Mess\u00adan\u00adlagen \u00fcber\u00adar\u00adbeiten\u201c, erkl\u00e4rt Gabler. Die Pr\u00fcf\u00adex\u00adperten bei HIGHVOLT nehmen daher schritt\u00adweise alle Mess- und Pr\u00fcf\u00adan\u00adlagen unter die Lupe und unter\u00adsu\u00adchen, wie sie die Kompo\u00adnenten an die neuen Anfor\u00adde\u00adrungen anpassen k\u00f6nnen. So l\u00e4sst sich etwa das Isolier\u00adver\u00adm\u00f6gen der synthe\u00adti\u00adschen Luft deut\u00adlich verbes\u00adsern, indem der Betriebs\u00addruck in den Anlagen von vier auf sieben Bar nahezu verdop\u00adpelt wird. Das bedingt wiederum dickere W\u00e4nde bei den Gef\u00e4\u00dfen, damit sie dem h\u00f6heren Druck stand\u00adhalten. <\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns are-vertically-aligned-center is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:40%\">\n<h2 class=\"wp-block-heading has-text-align-center no-margin-bottom\">Zukunfts\u00adsi\u00adcher<\/h2>\n\n\n\n<p class=\"has-text-align-center sans\" style=\"font-size:18px\">Luft birgt kein Risiko! Somit ist der Einsatz unab\u00adh\u00e4ngig von zuk\u00fcnf\u00adtigen Regu\u00adlie\u00adrungen dauer\u00adhaft m\u00f6glich.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:40%\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"685\" height=\"503\" src=\"https:\/\/onload.reinhausen.com\/de\/wp-content\/uploads\/sites\/25\/2025\/07\/Highvolt_Synthetische-Luft.webp\" alt class=\"wp-image-14031\" style=\"width:150px\" title=\"no-margin-bottom\" srcset=\"https:\/\/onload.reinhausen.com\/de\/wp-content\/uploads\/sites\/25\/2025\/07\/Highvolt_Synthetische-Luft.webp 685w, https:\/\/onload.reinhausen.com\/de\/wp-content\/uploads\/sites\/25\/2025\/07\/Highvolt_Synthetische-Luft-300x220.webp 300w, https:\/\/onload.reinhausen.com\/de\/wp-content\/uploads\/sites\/25\/2025\/07\/Highvolt_Synthetische-Luft-540x397.webp 540w\" sizes=\"auto, (max-width: 685px) 100vw, 685px\"><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading has-text-align-center no-margin-bottom no-margin-top\">Synthe\u00adti\u00adsche Luft<\/h2>\n\n\n\n<p class=\"has-text-align-center sans\" style=\"font-size:18px\">besteht aus Stick\u00adstoff und Sauer\u00adstoff.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:40%\">\n<h2 class=\"wp-block-heading has-text-align-center no-margin-top no-margin-bottom\">0 Treib\u00adhaus\u00adpo\u00adten\u00adtial<\/h2>\n\n\n\n<p class=\"has-text-align-center sans\" style=\"font-size:18px\">Synthe\u00adti\u00adsche Luft ist f\u00fcr das Klima v\u00f6llig unbe\u00addenk\u00adlich.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-text-align-left\">\u201eAuch die Isolier\u00adab\u00adst\u00e4nde m\u00fcssen wir erh\u00f6hen und die Elek\u00adtro\u00adden\u00adgeo\u00adme\u00adtrien anpassen. Insge\u00adsamt werden unsere Anlagen durch diese Ma\u00dfnahmen etwa 20 Prozent gr\u00f6\u00dfer, aber ansonsten bleiben alle Funk\u00adtio\u00adna\u00adli\u00adt\u00e4ten gleich\u201c, so Gabler. Da immer mehr Hersteller von GIS eben\u00adfalls zuneh\u00admend auf synthe\u00adti\u00adsche Luft setzen, sind die Systeme von HIGHVOLT mit ihnen kompa\u00adtibel. Aber auch bestehende Anlagen, die noch mit SF<sub>6<\/sub> betrieben werden, lassen sich mit den entspre\u00adchenden Adap\u00adtern weiterhin pr\u00fcfen. \u201eIn dieser Hinsicht sind unsere Systeme sehr flexibel\u201c, betont Gabler. Neben dem Umwelt\u00adaspekt hat synthe\u00adti\u00adsche Luft aber noch weitere Vorteile f\u00fcr Betreiber: So ist das Gashand\u00adling deut\u00adlich einfa\u00adcher, wie Gabler erkl\u00e4rt: \u201eWartungen sind mit SF6 deut\u00adlich zeit\u00adin\u00adten\u00adsiver, das Gas muss aufwendig abge\u00adsaugt werden und etliche Sicher\u00adheits\u00advor\u00adkeh\u00adrungen sind zum Beispiel auch w\u00e4hrend des Trans\u00adports notwendig \u2013 das alles entf\u00e4llt oder verein\u00adfacht sich.\u201c Auch die Anfor\u00adde\u00adrungen an das Mate\u00adrial sind bei synthe\u00adti\u00adscher Luft nicht so streng. Eben\u00adfalls ein wich\u00adtiger Punkt: Synthe\u00adti\u00adsche Luft ist leichter verf\u00fcgbar und deut\u00adlich kosten\u00adg\u00fcns\u00adtiger als SF<sub>6<\/sub>. Die erste Reso\u00adnanz\u00addrossel f\u00fcr die Wech\u00adsel\u00adspan\u00adnungs\u00adpr\u00fcf\u00adsys\u00adteme haben die HIGH\u00adVOLT-Inge\u00adnieure bereits an das neue Isolier\u00adme\u00addium ange\u00adpasst. \u201eDamit sind wir aktuell einer der ersten Hersteller, die Pr\u00fcf\u00adtechnik mit synthe\u00adti\u00adscher Luft auf den Markt bringen.\u201c Nach und nach folgen weitere Pr\u00fcf- und Mess\u00adsys\u00adteme, damit ab 2028 alle Typen\u00adreihen von HIGHVOLT mit synthe\u00adti\u00adscher Luft funk\u00adtio\u00adnieren.<\/p>\n\n\n\n<div style=\"height:60px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n\n\n<p><\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group mgznkr-elements mgznkr-box\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Rein\u00adhausen Inside<\/h3>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\">\n\n\n\n<p>Folgende Systeme von HIGHVOLT sind bereits ange\u00adpasst oder demn\u00e4chst mit synthe\u00adti\u00adscher Luft verf\u00fcgbar:<\/p>\n\n\n\n<h6 class=\"wp-block-heading\">2025<\/h6>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Wech\u00adsel\u00adspan\u00adnungs-Reso\u00adnanz\u00adpr\u00fcf\u00adsystem WRVG\/Resonanzdrossel f\u00fcr 340-kV-Pr\u00fcf\u00adspan\u00adnung<\/li>\n\n\n\n<li>Verlust\u00adleis\u00adtungs\u00admess\u00adsystem LiMOS f\u00fcr 100-kV-Pr\u00fcf\u00adspan\u00adnung<\/li>\n\n\n\n<li>MCP-Normal\u00adkon\u00adden\u00adsator<\/li>\n<\/ul>\n\n\n\n<h6 class=\"wp-block-heading\">Ab 2026<\/h6>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Verlust\u00adleis\u00adtungs\u00admess\u00adsystem LiMOS f\u00fcr 200-kV-Pr\u00fcf\u00adspan\u00adnung<\/li>\n\n\n\n<li>Wech\u00adsel\u00adspan\u00adnungs\u00adpr\u00fcf\u00adsystem WRVG f\u00fcr Pr\u00fcf\u00adspan\u00adnungen bis 680 kV<\/li>\n<\/ul>\n<\/div><\/div>\n\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group ansprechpartner\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<hr class=\"wp-block-separator has-alpha-channel-opacity\">\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/onload.reinhausen.com\/de\/wp-content\/uploads\/sites\/25\/2025\/07\/Highvolt-Dr-Tobias-Gabler.webp\" alt class=\"wp-image-14045\" style=\"width:150px\" srcset=\"https:\/\/onload.reinhausen.com\/de\/wp-content\/uploads\/sites\/25\/2025\/07\/Highvolt-Dr-Tobias-Gabler.webp 300w, https:\/\/onload.reinhausen.com\/de\/wp-content\/uploads\/sites\/25\/2025\/07\/Highvolt-Dr-Tobias-Gabler-150x150.webp 150w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\"><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">IHR ANSPRECHPARTNER<\/h2>\n\n\n\n<p><strong>Haben Sie Fragen zu gasiso\u00adlierten Pr\u00fcf- und Mess\u00adsys\u00adtemen?&nbsp;<\/strong>Dr. Tobias Gabler ist f\u00fcr Sie da:<br><a href=\"&#x6d;&#97;i&#x6c;&#x74;&#111;:&#x54;&#x2e;&#71;a&#x62;&#x6c;&#101;r&#x40;&#x68;&#105;g&#x68;&#118;&#111;l&#x74;&#46;c&#x6f;&#x6d;\" target=\"_blank\" rel=\"noreferrer noopener\"><i class=\"wpcmsdev-icon fa fa-envelope-o\"><\/i><\/a> \u2009<a href=\"&#109;&#x61;&#105;&#x6c;t&#x6f;:&#84;&#x2e;&#71;&#x61;b&#x6c;e&#114;&#x40;&#104;&#x69;g&#x68;v&#111;&#x6c;&#116;&#x2e;c&#x6f;m\" target=\"_blank\" rel=\"noreferrer noopener\">T&#46;&#71;&#97;&#98;&#x6c;&#x65;&#x72;&#x40;&#x68;ig&#104;&#118;&#111;&#x6c;&#x74;&#x2e;&#x63;&#x6f;m<\/a><\/p>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Schwe\u00adfel\u00adhexa\u00adfluorid ist ein hervor\u00adra\u00adgendes Isoliergas f\u00fcr elek\u00adtri\u00adsche Anwen\u00addungen, hat aber eine kata\u00adstro\u00adphale Treib\u00adhaus\u00adbi\u00adlanz. Eine EU-Verord\u00adnung verbietet daher sukzes\u00adsive den Einsatz. HIGHVOLT ist darauf vorbe\u00adreitet und macht seine gasiso\u00adlierten Pr\u00fcf- und Mess\u00adsys\u00adteme zukunfts\u00adsi\u00adcher.<\/p>\n","protected":false},"author":4,"featured_media":14144,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"wp_typography_post_enhancements_disabled":false,"footnotes":""},"categories":[43,1],"tags":[],"class_list":["post-14005","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-07-2025","category-onload"],"acf":[],"_links":{"self":[{"href":"https:\/\/onload.reinhausen.com\/de\/wp-json\/wp\/v2\/posts\/14005","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/onload.reinhausen.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/onload.reinhausen.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/onload.reinhausen.com\/de\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/onload.reinhausen.com\/de\/wp-json\/wp\/v2\/comments?post=14005"}],"version-history":[{"count":87,"href":"https:\/\/onload.reinhausen.com\/de\/wp-json\/wp\/v2\/posts\/14005\/revisions"}],"predecessor-version":[{"id":15728,"href":"https:\/\/onload.reinhausen.com\/de\/wp-json\/wp\/v2\/posts\/14005\/revisions\/15728"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/onload.reinhausen.com\/de\/wp-json\/wp\/v2\/media\/14144"}],"wp:attachment":[{"href":"https:\/\/onload.reinhausen.com\/de\/wp-json\/wp\/v2\/media?parent=14005"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/onload.reinhausen.com\/de\/wp-json\/wp\/v2\/categories?post=14005"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/onload.reinhausen.com\/de\/wp-json\/wp\/v2\/tags?post=14005"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}