{"id":4493,"date":"2019-07-08T21:30:45","date_gmt":"2019-07-08T19:30:45","guid":{"rendered":"https:\/\/onload.reinhausen.com\/de\/?p=4493"},"modified":"2023-06-02T10:09:18","modified_gmt":"2023-06-02T08:09:18","slug":"7-tipps-vom-trafo-doc","status":"publish","type":"post","link":"https:\/\/onload.reinhausen.com\/de\/07-2019\/7-tipps-vom-trafo-doc\/","title":{"rendered":"7 Tipps vom Trafo-Doc"},"content":{"rendered":"\n<div class=\"wpcmsdev-accordion\">\n<div class=\"accordion-item\">\n<h3 class=\"accordion-item-title\"><a href=\"#accordion-item-wartungsintervalle-einhalten\"><i class=\"fa fa-plus icon-for-inactive\"><\/i><i class=\"fa fa-minus icon-for-active\"><\/i>WARTUNGSINTERVALLE EINHALTEN<\/a><\/h3>\n<div id=\"accordion-item-wartungsintervalle-einhalten\" class=\"accordion-item-content\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-4580 size-full\" src=\"https:\/\/onload.reinhausen.com\/de\/wp-content\/uploads\/sites\/25\/2019\/07\/LKW-e1562223302283.jpg\" alt width=\"150\" height=\"128\">Halten Sie die Wartungs\u00adin\u00adter\u00advalle f\u00fcr den Last\u00adstufenschalter ein. Der Termin der n\u00e4chsten Wartung orien\u00adtiert sich entweder an der Einsatz\u00addauer des Last\u00adstu\u00adfen\u00adschal\u00adters oder der Anzahl der get\u00e4\u00adtigten Schal\u00adtungen. Bei einigen Schal\u00adter\u00adtypen ist sie nach sieben Jahren oder nach 70.000 Schal\u00adtungen f\u00e4llig. Entschei\u00addend ist, was eher eintritt.<\/p>\n<\/div>\n<\/div>\n<div class=\"accordion-item\">\n<h3 class=\"accordion-item-title\"><a href=\"#accordion-item-qualifiziertes-personal\"><i class=\"fa fa-plus icon-for-inactive\"><\/i><i class=\"fa fa-minus icon-for-active\"><\/i>QUALIFIZIERTES PERSONAL<\/a><\/h3>\n<div id=\"accordion-item-qualifiziertes-personal\" class=\"accordion-item-content\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-4586\" src=\"https:\/\/onload.reinhausen.com\/de\/wp-content\/uploads\/sites\/25\/2019\/07\/Stern.jpg\" alt width=\"150\" height=\"150\">Ein Trans\u00adfor\u00admator ist etwas f\u00fcr Experten, denn nicht jeder kennt die spezi\u00adellen Anspr\u00fcche Ihres Trans\u00adfor\u00adma\u00adtors und des Stufen\u00adschal\u00adters. Die Wartung durch quali\u00adfi\u00adziertes Personal bietet die Chance, fr\u00fch\u00adzeitig Unre\u00adgel\u00adm\u00e4\u00ad\u00dfig\u00adkeiten im Betrieb zu erkennen.<\/p>\n<\/div>\n<\/div>\n<div class=\"accordion-item\">\n<h3 class=\"accordion-item-title\"><a href=\"#accordion-item-oel-untersuchen\"><i class=\"fa fa-plus icon-for-inactive\"><\/i><i class=\"fa fa-minus icon-for-active\"><\/i>\u00d6l UNTERSUCHEN<\/a><\/h3>\n<div id=\"accordion-item-oel-untersuchen\" class=\"accordion-item-content\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-4589\" src=\"https:\/\/onload.reinhausen.com\/de\/wp-content\/uploads\/sites\/25\/2019\/07\/Tropfen_1.jpg\" alt width=\"157\" height=\"153\">Analy\u00adsieren Sie mindes\u00adtens einmal im Jahr das \u00d6l. \u00c4hnlich wie beim Blut\u00adbild, das Aufschluss \u00fcber die Gesund\u00adheit eines Pati\u00adenten gibt, sagt die Qualit\u00e4t des \u00d6ls etwas \u00fcber die Fitness des Trans\u00adfor\u00adma\u00adtors aus. Ausschlag\u00adge\u00adbend f\u00fcr eine gute \u00d6lqua\u00adlit\u00e4t sind zum Beispiel ein nied\u00adriger Wasser\u00adge\u00adhalt, eine hohe Grenz\u00adfl\u00e4\u00adchen\u00adspan\u00adnung, eine hohe dielek\u00adtri\u00adsche Festig\u00adkeit sowie ein nied\u00adriger Leis\u00adtungs\u00adfaktor.<\/p>\n<\/div>\n<\/div>\n<div class=\"accordion-item\">\n<h3 class=\"accordion-item-title\"><a href=\"#accordion-item-dga-analyse\"><i class=\"fa fa-plus icon-for-inactive\"><\/i><i class=\"fa fa-minus icon-for-active\"><\/i>DGA-ANALYSE<\/a><\/h3>\n<div id=\"accordion-item-dga-analyse\" class=\"accordion-item-content\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-4583\" src=\"https:\/\/onload.reinhausen.com\/de\/wp-content\/uploads\/sites\/25\/2019\/07\/Lupe.jpg\" alt width=\"150\" height=\"150\">Eine tiefer\u00adge\u00adhende Analyse umfasst die zus\u00e4tz\u00adliche Unter\u00adsu\u00adchung der Gase. Die \u201eDissolved Gas Analysis\u201c (DGA) empfehlen wir eben\u00adfalls j\u00e4hr\u00adlich. Dabei pr\u00fcfen wir das Verh\u00e4ltnis der im \u00d6l gel\u00f6sten Gase. Jedes der Gase wird durch einen bestimmten Zustand oder bestimmte Bedin\u00adgungen im Trans\u00adfor\u00admator erzeugt. Nach der Analyse kennen wir den Gesund\u00adheits\u00adzu\u00adstand der Trafos.<\/p>\n<\/div>\n<\/div>\n<div class=\"accordion-item\">\n<h3 class=\"accordion-item-title\"><a href=\"#accordion-item-oelstand-pruefen\"><i class=\"fa fa-plus icon-for-inactive\"><\/i><i class=\"fa fa-minus icon-for-active\"><\/i>\u00d6LSTAND PR\u00dcFEN<\/a><\/h3>\n<div id=\"accordion-item-oelstand-pruefen\" class=\"accordion-item-content\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-4584\" src=\"https:\/\/onload.reinhausen.com\/de\/wp-content\/uploads\/sites\/25\/2019\/07\/Oel-Pruefen.jpg\" alt width=\"150\" height=\"150\">Pr\u00fcfen Sie regel\u00adm\u00e4\u00dfig den \u00d6lstand: Da das \u00d6l gleich\u00adzeitig als Isolator, K\u00fchl- und Schmier\u00admittel dient, muss regel\u00adm\u00e4\u00dfig kontrol\u00adliert werden, ob Haupt\u00adtank, Last\u00adstu\u00adfen\u00adschal\u00adter\u00adbe\u00adh\u00e4lter und Durch\u00adf\u00fch\u00adrungen ausrei\u00adchend gef\u00fcllt sind.<\/p>\n<\/div>\n<\/div>\n<div class=\"accordion-item\">\n<h3 class=\"accordion-item-title\"><a href=\"#accordion-item-entfeuchtung-checken\"><i class=\"fa fa-plus icon-for-inactive\"><\/i><i class=\"fa fa-minus icon-for-active\"><\/i>ENTFEUCHTUNG CHECKEN<\/a><\/h3>\n<div id=\"accordion-item-entfeuchtung-checken\" class=\"accordion-item-content\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-4585\" src=\"https:\/\/onload.reinhausen.com\/de\/wp-content\/uploads\/sites\/25\/2019\/07\/Regen.jpg\" alt width=\"150\" height=\"150\">\u00dcber\u00adpr\u00fcfen Sie regel\u00adm\u00e4\u00dfig den Luft\u00adent\u00adfeuchter, um sicher\u00ad\u00adzu\u00adstellen, dass keine unzu\u00adl\u00e4s\u00adsige Feuch\u00adtig\u00adkeit von au\u00dfen in den \u00d6laus\u00addehner eintritt. Denn Feuch\u00adtig\u00adkeit im \u00d6l redu\u00adziert die Lebens\u00addauer des Trans\u00adfor\u00adma\u00adtors. Lassen Sie einen Experten pr\u00fcfen, ob er zuver\u00adl\u00e4ssig arbeitet oder ob das f\u00fcr den Wasser\u00adentzug wich\u00adtige Sili\u00adkagel ausge\u00adtauscht werden sollte.<\/p>\n<\/div>\n<\/div>\n<div class=\"accordion-item\">\n<h3 class=\"accordion-item-title\"><a href=\"#accordion-item-regelmaessige-inspektion\"><i class=\"fa fa-plus icon-for-inactive\"><\/i><i class=\"fa fa-minus icon-for-active\"><\/i>REGEL\u00adM\u00c4\u00ad\u00dfIGE INSPEKTION<\/a><\/h3>\n<div id=\"accordion-item-regelmaessige-inspektion\" class=\"accordion-item-content\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-4582\" src=\"https:\/\/onload.reinhausen.com\/de\/wp-content\/uploads\/sites\/25\/2019\/07\/Korrekt.jpg\" alt width=\"150\" height=\"150\">Eine regel\u00adm\u00e4\u00ad\u00dfige Inspek\u00adtion ist wichtig. Unsere Spezia\u00adlisten pr\u00fcfen alle instal\u00adlierten Kompo\u00adnenten, wie Durch\u00adf\u00fch\u00adrungen, L\u00fcfter, Anzeigen, Ventile, Motor\u00adan\u00adtrieb und den Schalt\u00adschrank, um beispiels\u00adweise Leckagen oder Korro\u00adsion fr\u00fch\u00adzeitig zu erkennen. Mit der Funktions\u00adkontrolle der Schutz\u00adein\u00adrich\u00adtungen stellen wir sicher, dass sich der Trans\u00adfor\u00admator im Fehler\u00adfall sofort abschaltet.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<hr class=\"yellow\">\n<h2>IHR ANSPRECHPARTNER<\/h2>\n<p><strong>Richard Bates<\/strong> ist Director Asset&nbsp;Manage\u00adment Busi\u00adness Rein\u00adhausen Manu\u00adfac\u00adtu\u00adring USA. Neben Stufen\u00adschal\u00adtern bietet das Toch\u00adter\u00adun\u00adter\u00adnehmen umfang\u00adreiche Services an. Dazu z\u00e4hlen&nbsp; umfas\u00adsende Diagno\u00adse\u00adleis\u00adtungen, Wartung von Stufen\u00adschal\u00adtern (auch Fremd\u00adfa\u00adbri\u00adkate) durch Premium-Service-Provider, Turn-Key-Retro\u00adfit\u00adpro\u00adjekte sowie Instal\u00adla\u00adtion und Inbe\u00adtrieb\u00adnahme von neuen Trans\u00adfor\u00adma\u00adtoren. Rund 50 Service\u00adtech\u00adniker sind daf\u00fcr im Einsatz.<\/p>\n<p><a href=\"&#x6d;&#x61;&#105;lt&#x6f;&#x3a;&#82;&#46;B&#x61;&#x74;&#101;&#115;&#64;&#x75;&#x73;&#x2e;&#114;ei&#x6e;&#x68;&#97;&#117;s&#x65;&#x6e;&#46;&#99;o&#x6d;\"><i class=\"wpcmsdev-icon fa fa-envelope-o\"><\/i> &#82;&#x2e;&#x42;a&#116;&#x65;s&#64;&#x75;&#x73;&#46;&#x72;&#x65;i&#110;&#x68;a&#117;&#x73;&#x65;&#110;&#x2e;&#x63;o&#109;<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Der Trans\u00adfor\u00admator steht st\u00e4ndig unter Span\u00adnung. Kein Wunder also, dass er und sein Herz\u00adst\u00fcck, der Last\u00adstu\u00adfen\u00adschalter, regel\u00adm\u00e4\u00dfig \u00fcber\u00adpr\u00fcft werden m\u00fcssen, um ein langes und sicheres Leben f\u00fchren zu k\u00f6nnen. Richard Bates, Director Asset Manage\u00adment Busi\u00adness bei Rein\u00adhausen Manu\u00adfac\u00adtu\u00adring USA, war viele Jahre als Tech\u00adniker im Au\u00dfen\u00addienst sowie als Service- und Betriebs\u00adleiter t\u00e4tig und wei\u00df, was f\u00fcr einen sicheren Trafo\u00adbe\u00adtrieb wichtig ist.<\/p>\n","protected":false},"author":27,"featured_media":4594,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"wp_typography_post_enhancements_disabled":false,"footnotes":""},"categories":[6],"tags":[],"class_list":["post-4493","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-07-2019"],"acf":[],"_links":{"self":[{"href":"https:\/\/onload.reinhausen.com\/de\/wp-json\/wp\/v2\/posts\/4493","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/onload.reinhausen.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/onload.reinhausen.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/onload.reinhausen.com\/de\/wp-json\/wp\/v2\/users\/27"}],"replies":[{"embeddable":true,"href":"https:\/\/onload.reinhausen.com\/de\/wp-json\/wp\/v2\/comments?post=4493"}],"version-history":[{"count":8,"href":"https:\/\/onload.reinhausen.com\/de\/wp-json\/wp\/v2\/posts\/4493\/revisions"}],"predecessor-version":[{"id":9536,"href":"https:\/\/onload.reinhausen.com\/de\/wp-json\/wp\/v2\/posts\/4493\/revisions\/9536"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/onload.reinhausen.com\/de\/wp-json\/wp\/v2\/media\/4594"}],"wp:attachment":[{"href":"https:\/\/onload.reinhausen.com\/de\/wp-json\/wp\/v2\/media?parent=4493"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/onload.reinhausen.com\/de\/wp-json\/wp\/v2\/categories?post=4493"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/onload.reinhausen.com\/de\/wp-json\/wp\/v2\/tags?post=4493"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}