{"id":1717,"date":"2017-04-04T22:30:17","date_gmt":"2017-04-04T20:30:17","guid":{"rendered":"https:\/\/www.mag4web.com\/onload-de\/?p=1717"},"modified":"2023-05-30T10:11:02","modified_gmt":"2023-05-30T08:11:02","slug":"it-works-just-15-minutes-per-test-piece","status":"publish","type":"post","link":"https:\/\/onload.reinhausen.com\/en\/05-2017\/it-works-just-15-minutes-per-test-piece\/","title":{"rendered":"It works. Just 15 minutes per test piece"},"content":{"rendered":"<hr class=\"yellow\">\n<p><span class=\"initial\">D<\/span>istri\u00adb\u00adu\u00adtion trans\u00adform\u00aders are a mass prod\u00aduct. But before they can leave pro\u00adduc\u00adtion, every trans\u00adformer has to under\u00adgo inten\u00adsive elec\u00adtri\u00adcal test\u00ading. The DiTAS auto\u00admat\u00aded test sys\u00adtem from HIGHVOLT can test the gen\u00ader\u00adal oper\u00adat\u00ading para\u00adme\u00adters, load char\u00adac\u00adter\u00adis\u00adtics, and insu\u00adla\u00adtion in under 15 min\u00adutes. This is pos\u00adsi\u00adble because the sys\u00adtem switch\u00ades auto\u00admat\u00adi\u00adcal\u00adly between test cir\u00adcuits rather than man\u00adu\u00adal\u00adly. Fur\u00adther\u00admore, a lift\u00ading plat\u00adform allows dif\u00adfer\u00adent trans\u00adformer sizes to be con\u00adnect\u00aded quick\u00adly and eas\u00adi\u00adly.<\/p>\n<p>&nbsp;<\/p>\n\n<div class=\"wpcmsdev-box\">\n<div class=\"box-content\">\n<h5>Find out more about the test procedure in our white paper:<\/h5>\n<h3><a href=\"https:\/\/onload.reinhausen.com\/en\/wp-content\/uploads\/sites\/26\/2017\/04\/On-load-1_Automated-test-systems-for-distribution-transformers.pdf\" target=\"_blank\" rel=\"noopener\"><i class=\"fa fa-file-pdf-o\" style=\"margin-right: 20px;float: left;font-size: 2.4em\"><\/i>HIGH VOLT: Automated test systems for Distribution transformers DiTAS<\/a><\/h3>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Distri\u00adb\u00adu\u00adtion trans\u00adform\u00aders are a mass prod\u00aduct. But before they can leave pro\u00adduc\u00adtion, every trans\u00adformer has to under\u00adgo inten\u00adsive elec\u00adtri\u00adcal test\u00ading. The DiTAS auto\u00admat\u00aded test sys\u00adtem from HIGHVOLT can\u2026<\/p>\n","protected":false},"author":27,"featured_media":1791,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"wp_typography_post_enhancements_disabled":false,"footnotes":""},"categories":[17,2],"tags":[],"class_list":["post-1717","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-editorial-short-article","category-05-2017"],"acf":[],"_links":{"self":[{"href":"https:\/\/onload.reinhausen.com\/en\/wp-json\/wp\/v2\/posts\/1717","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/onload.reinhausen.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/onload.reinhausen.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/onload.reinhausen.com\/en\/wp-json\/wp\/v2\/users\/27"}],"replies":[{"embeddable":true,"href":"https:\/\/onload.reinhausen.com\/en\/wp-json\/wp\/v2\/comments?post=1717"}],"version-history":[{"count":1,"href":"https:\/\/onload.reinhausen.com\/en\/wp-json\/wp\/v2\/posts\/1717\/revisions"}],"predecessor-version":[{"id":8374,"href":"https:\/\/onload.reinhausen.com\/en\/wp-json\/wp\/v2\/posts\/1717\/revisions\/8374"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/onload.reinhausen.com\/en\/wp-json\/wp\/v2\/media\/1791"}],"wp:attachment":[{"href":"https:\/\/onload.reinhausen.com\/en\/wp-json\/wp\/v2\/media?parent=1717"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/onload.reinhausen.com\/en\/wp-json\/wp\/v2\/categories?post=1717"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/onload.reinhausen.com\/en\/wp-json\/wp\/v2\/tags?post=1717"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}