{"id":17204,"date":"2026-07-10T12:03:59","date_gmt":"2026-07-10T10:03:59","guid":{"rendered":"https:\/\/onload.reinhausen.com\/de\/?p=17204"},"modified":"2026-07-10T12:03:59","modified_gmt":"2026-07-10T10:03:59","slug":"reactive-power-compensation-system-for-renewable-energy-plants","status":"publish","type":"post","link":"https:\/\/onload.reinhausen.com\/en\/07-2026\/reactive-power-compensation-system-for-renewable-energy-plants\/","title":{"rendered":"Reactive Power for the Energy Transition"},"content":{"rendered":"\n<hr class=\"wp-block-separator has-alpha-channel-opacity\">\n\n\n\n<p class=\"has-drop-cap wp-block-paragraph\">With\u00adout reac\u00adtive pow\u00ader, there can be no sta\u00adble pow\u00ader grid since it is fun\u00adda\u00admen\u00adtal\u00adly nec\u00ades\u00adsary for build\u00ading up and main\u00adtain\u00ading volt\u00adage. How\u00adev\u00ader, with the phase-out of coal and nuclear ener\u00adgy, the sources of reac\u00adtive pow\u00ader \u2013 name\u00adly large pow\u00ader plants \u2013 are grad\u00adu\u00adal\u00adly dis\u00adap\u00adpear\u00ading, and with them an impor\u00adtant tool for keep\u00ading the grid volt\u00adage sta\u00adble. At the same time, the num\u00adber of solar and wind pow\u00ader plants has sky\u00adrock\u00adet\u00aded in recent years, and their feed-in fluc\u00adtu\u00adates depend\u00ading on weath\u00ader con\u00addi\u00adtions. This espe\u00adcial\u00adly puts mas\u00adsive pres\u00adsure on the 110 kV high-volt\u00adage grids of dis\u00adtri\u00adb\u00adu\u00adtion sys\u00adtem oper\u00ada\u00adtors for whom ensur\u00ading a sta\u00adble volt\u00adage under these con\u00addi\u00adtions is a chal\u00adlenge. That is why many coun\u00adtries now require renew\u00adable ener\u00adgy plants to pro\u00advide suf\u00adfi\u00adcient reac\u00adtive pow\u00ader to main\u00adtain volt\u00adage sta\u00adbil\u00adi\u00adty.<\/p>\n\n\n\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/onload.reinhausen.com\/en\/wp-content\/uploads\/sites\/26\/2026\/07\/Reinhausen-Gridcon-Station-Control-Room-768x1024.webp\" alt class=\"wp-image-17208\" srcset=\"https:\/\/onload.reinhausen.com\/en\/wp-content\/uploads\/sites\/26\/2026\/07\/Reinhausen-Gridcon-Station-Control-Room-768x1024.webp 768w, https:\/\/onload.reinhausen.com\/en\/wp-content\/uploads\/sites\/26\/2026\/07\/Reinhausen-Gridcon-Station-Control-Room-225x300.webp 225w, https:\/\/onload.reinhausen.com\/en\/wp-content\/uploads\/sites\/26\/2026\/07\/Reinhausen-Gridcon-Station-Control-Room-1152x1536.webp 1152w, https:\/\/onload.reinhausen.com\/en\/wp-content\/uploads\/sites\/26\/2026\/07\/Reinhausen-Gridcon-Station-Control-Room-540x720.webp 540w, https:\/\/onload.reinhausen.com\/en\/wp-content\/uploads\/sites\/26\/2026\/07\/Reinhausen-Gridcon-Station-Control-Room-1080x1440.webp 1080w, https:\/\/onload.reinhausen.com\/en\/wp-content\/uploads\/sites\/26\/2026\/07\/Reinhausen-Gridcon-Station-Control-Room.webp 1200w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\"><figcaption class=\"wp-element-caption\">The con\u00adtrol room con\u00adtains the con\u00adtrol cab\u00adi\u00adnet for con\u00adtrol\u00adling and pro\u00adtect\u00ading the reac\u00adtive pow\u00ader stages. Con\u00adnec\u00adtion to a high\u00ader-lev\u00adel SCADA or con\u00adtrol sys\u00adtem is also pos\u00adsi\u00adble.<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\" id=\"drosseln-bild\">\n<figure class=\"wp-block-image size-large\"><a href=\"\/en\/#1\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/onload.reinhausen.com\/en\/wp-content\/uploads\/sites\/26\/2026\/07\/Reinhausen-Gridcon-Station-reactors-banks-Kopie-1024x576.webp\" alt class=\"wp-image-17467\" srcset=\"https:\/\/onload.reinhausen.com\/en\/wp-content\/uploads\/sites\/26\/2026\/07\/Reinhausen-Gridcon-Station-reactors-banks-Kopie-1024x576.webp 1024w, https:\/\/onload.reinhausen.com\/en\/wp-content\/uploads\/sites\/26\/2026\/07\/Reinhausen-Gridcon-Station-reactors-banks-Kopie-300x169.webp 300w, https:\/\/onload.reinhausen.com\/en\/wp-content\/uploads\/sites\/26\/2026\/07\/Reinhausen-Gridcon-Station-reactors-banks-Kopie-768x432.webp 768w, https:\/\/onload.reinhausen.com\/en\/wp-content\/uploads\/sites\/26\/2026\/07\/Reinhausen-Gridcon-Station-reactors-banks-Kopie-1536x864.webp 1536w, https:\/\/onload.reinhausen.com\/en\/wp-content\/uploads\/sites\/26\/2026\/07\/Reinhausen-Gridcon-Station-reactors-banks-Kopie-540x304.webp 540w, https:\/\/onload.reinhausen.com\/en\/wp-content\/uploads\/sites\/26\/2026\/07\/Reinhausen-Gridcon-Station-reactors-banks-Kopie-1080x608.webp 1080w, https:\/\/onload.reinhausen.com\/en\/wp-content\/uploads\/sites\/26\/2026\/07\/Reinhausen-Gridcon-Station-reactors-banks-Kopie.webp 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\"><\/a><figcaption class=\"wp-element-caption\">The capac\u00adi\u00adtor banks&nbsp;<mark style=\"background-color:#fcf03c\" class=\"has-inline-color has-accent-color\"><a href=\"\/en\/#drosseln-bild\" data-type=\"internal\" data-id=\"#drosseln-bild\" class=\"sans\">1<\/a><\/mark> gen\u00ader\u00adate capac\u00adi\u00adtive reac\u00adtive pow\u00ader and thus sup\u00adport volt\u00adage main\u00adte\u00adnance in the medi\u00adum\u00advolt\u00adage grid. They are con\u00adfig\u00adured in up to three stages and can be flex\u00adi\u00adbly acti\u00advat\u00aded depend\u00ading on grid require\u00adments. DThe reac\u00adtors&nbsp;<mark style=\"background-color:#fcf03c\" class=\"has-inline-color has-accent-color\"><a href=\"\/en\/#drosseln-bild\" data-type=\"internal\" data-id=\"#drosseln-bild\" class=\"sans\">2<\/a><\/mark> from Rein\u00adhausen sub\u00adsidiary Hans von Man\u00adgoldt pro\u00adtect the capac\u00adi\u00adtors from har\u00admon\u00adics in the grid. They lim\u00adit the result\u00ading cur\u00adrents and pre\u00advent dam\u00adage to the capac\u00adi\u00adtors.<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Rein\u00adhausen Pow\u00ader Qual\u00adi\u00adty devel\u00adoped a stan\u00addard\u00adized solu\u00adtion for reac\u00adtive pow\u00ader pro\u00advi\u00adsion for such plants as ear\u00adly as the begin\u00adning of the 2010s, enabling oper\u00ada\u00adtors to eas\u00adi\u00adly meet the tech\u00adni\u00adcal con\u00adnec\u00adtion require\u00adments: the GRIDCON<sup>\u00ae<\/sup> STATION. Thomas Simon, Senior Sales Man\u00adag\u00ader at Rein\u00adhausen Pow\u00ader Qual\u00adi\u00adty, explains: \u201cWe offer our reac\u00adtive pow\u00ader com\u00adpen\u00adsa-<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">tion sys\u00adtem in single\u2011, two- or three\u00adstage con\u00adfig\u00adu\u00adra\u00adtions, depend\u00ading on require\u00adments.\u201d The pow\u00ader qual\u00adi\u00adty experts at Rein\u00adhausen han\u00addle the com\u00adplete engi\u00adneer\u00ading process, from sys\u00adtem design and pri\u00adma\u00adry tech\u00adnol\u00ado\u00adgy, through struc\u00adtur\u00adal sta\u00adbil\u00adi\u00adty cal\u00adcu\u00adla\u00adtions, to the plan\u00adning of sec\u00adondary tech\u00adnol\u00ado\u00adgy with a com\u00adplete cir\u00adcuit dia\u00adgram and the deter\u00admi\u00adna\u00adtion of pro\u00adtec\u00adtion set\u00adtings.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Reactive power made easy<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">What makes this unique is that the entire sys\u00adtem \u2013 com\u00adpris\u00ading con\u00adtrol units, capac\u00adi\u00adtor banks, and reac\u00adtors \u2013 is pre\u00adfab\u00adri\u00adcat\u00aded at the fac\u00adto\u00adry by a part\u00adner as a light\u00adweight con\u00adcrete sta\u00adtion. \u201cAfter fac\u00adto\u00adry accep\u00adtance test\u00ading, which we over\u00adsee, a truck deliv\u00aders the ready to-con\u00adnect com\u00adpen\u00adsa\u00adtion sys\u00adtem direct\u00adly to the instal\u00adla\u00adtion site. There, one of our engi\u00adneers assists with com\u00admis\u00adsion\u00ading,\u201d Simon explains. Rein\u00adhausen ser\u00advice tech\u00adni\u00adcians also assist with main\u00adte\u00adnance and repairs dur\u00ading ongo\u00ading oper\u00ada\u00adtions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The GRIDCON<sup>\u00ae<\/sup> STATION allows oper\u00ada\u00adtors to do more than just meet grid con\u00adnec\u00adtion require\u00adments: \u201cBy pro\u00advid\u00ading reac\u00adtive pow\u00ader, plant oper\u00ada\u00adtors can feed in the max\u00adi\u00admum active pow\u00ader while simul\u00adta\u00adne\u00adous\u00adly meet\u00ading high over-excit\u00aded reac\u00adtive pow\u00ader require\u00adments, there\u00adby achiev\u00ading the best pos\u00adsi\u00adble rev\u00adenue,\u201d explains Simon.<\/p>\n\n\n\n<div class=\"wp-block-group mgznkr-box\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<h3 id=\"boxinhalt-hier-einfugen\" class=\"wp-block-heading\">The solution at a glance<\/h3>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\">\n\n\n\n<p class=\"wp-block-paragraph\">The entire sys\u00adtem is housed in a weath\u00ader-resis\u00adtant pre\u00adcast con\u00adcrete build\u00ading and can be installed direct\u00adly in the sub\u00adsta\u00adtion of the renew\u00adable ener\u00adgy plant using the plug-and-play prin\u00adci\u00adple. <a href=\"https:\/\/www.reinhausen.com\/productdetail\/power-quality\/gridcon-module-station\" target=\"_blank\" rel=\"noreferrer noopener\">The GRIDCON<sup>\u00ae<\/sup> STATION is avail\u00adable in 1\u2011, 2\u2011, and 3\u2011stage con\u00adfig\u00adu\u00adra\u00adtions.<\/a> Each stage can pro\u00advide up to 8 Mvar of over-excit\u00aded reac\u00adtive pow\u00ader at a volt\u00adage of 31.5 kV or 33 kV.<\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group ansprechpartner\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<hr class=\"wp-block-separator has-alpha-channel-opacity\">\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"400\" src=\"https:\/\/onload.reinhausen.com\/en\/wp-content\/uploads\/sites\/26\/2026\/07\/Thomas_Simon_607-172_1000px_SW_02RD-Kopie.webp\" alt class=\"wp-image-17205\" style=\"width:150px\" srcset=\"https:\/\/onload.reinhausen.com\/en\/wp-content\/uploads\/sites\/26\/2026\/07\/Thomas_Simon_607-172_1000px_SW_02RD-Kopie.webp 400w, https:\/\/onload.reinhausen.com\/en\/wp-content\/uploads\/sites\/26\/2026\/07\/Thomas_Simon_607-172_1000px_SW_02RD-Kopie-300x300.webp 300w, https:\/\/onload.reinhausen.com\/en\/wp-content\/uploads\/sites\/26\/2026\/07\/Thomas_Simon_607-172_1000px_SW_02RD-Kopie-150x150.webp 150w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\"><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">YOUR CONTACT<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Do you have ques\u00adtions about the GRIDCON<sup>\u00ae<\/sup> STATION?&nbsp;<br><\/strong>Thomas Simon is there for you:<br><i class=\"wpcmsdev-icon fa fa-envelope-o\"><\/i>\u2009 <a href=\"&#x6d;a&#x69;&#108;&#x74;&#111;:&#x54;&#46;&#x53;&#105;&#x6d;&#111;n&#x40;&#114;&#x65;&#105;n&#x68;a&#x75;&#115;&#x65;&#110;&#46;&#x63;o&#x6d;\" target=\"_blank\" rel=\"noreferrer noopener\">&#x54;&#x2e;&#83;i&#x6d;&#x6f;&#110;&#64;r&#x65;&#x69;&#110;h&#x61;&#x75;&#115;&#101;n&#x2e;&#x63;&#111;m<\/a><\/p>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>With the GRIDCON<sup>\u00ae<\/sup> STATION, Rein\u00adhausen devel\u00adoped a stan\u00addard\u00adized reac\u00adtive pow\u00ader com\u00adpen\u00adsa\u00adtion sys\u00adtem for renew\u00adable ener\u00adgy plants 15 years ago, ensur\u00ading they can be safe\u00adly con\u00adnect\u00aded to the grid.<\/p>\n","protected":false},"author":33,"featured_media":17206,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"wp_typography_post_enhancements_disabled":false,"footnotes":""},"categories":[48,1],"tags":[],"class_list":["post-17204","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-07-2026","category-onload"],"acf":[],"_links":{"self":[{"href":"https:\/\/onload.reinhausen.com\/en\/wp-json\/wp\/v2\/posts\/17204","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/onload.reinhausen.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/onload.reinhausen.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/onload.reinhausen.com\/en\/wp-json\/wp\/v2\/users\/33"}],"replies":[{"embeddable":true,"href":"https:\/\/onload.reinhausen.com\/en\/wp-json\/wp\/v2\/comments?post=17204"}],"version-history":[{"count":4,"href":"https:\/\/onload.reinhausen.com\/en\/wp-json\/wp\/v2\/posts\/17204\/revisions"}],"predecessor-version":[{"id":17834,"href":"https:\/\/onload.reinhausen.com\/en\/wp-json\/wp\/v2\/posts\/17204\/revisions\/17834"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/onload.reinhausen.com\/en\/wp-json\/wp\/v2\/media\/17206"}],"wp:attachment":[{"href":"https:\/\/onload.reinhausen.com\/en\/wp-json\/wp\/v2\/media?parent=17204"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/onload.reinhausen.com\/en\/wp-json\/wp\/v2\/categories?post=17204"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/onload.reinhausen.com\/en\/wp-json\/wp\/v2\/tags?post=17204"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}